XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder Configuring the ViconNet System 123
4. Click . The Macro Editor window changes and displays the Macro area in the
middle of the window. This section of the window is where you define the sequence of commands for
each macro.
5. In the Macro Name field, enter a logical name for the macro, for example, Front Entrance External
Cameras or Emergency – All Cameras Recording.
NOTE: The User Name is displayed automatically according to your log in information.
6. (Optional) In the Description field, enter a brief textual description of the macro.
7. Add the first command by selecting the required command type, as follows:
Record & Display: Simultaneously records and displays live video/audio from the selected
camera/microphone.
Record: Only records live video/audio from the selected camera/microphone.
Display: Only displays live video/audio from the selected camera/microphone.
Pause: Pauses all recording and displaying actions between operations.
Relay: Activates the selected relay.
Send Alarm: Automatically forwards alarm events to the destination site you specify. This causes
an alarm notification message to be displayed on the destination site.
Remote Macro: Automatically executes the selected macro on the destination site you specify.
Send Email: Automatically sends an email to the Email address you specify.
Send Text Message: Automatically sends a text message to the telephone number you specify.