118 Configuring the ViconNet System XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder
To activate the RVS mechanism (default=activated):
1. From the ViconNet Main window, click . The Setup Site Selection window is displayed,
showing a list of all currently connected transmitters and Workstations, as shown on page 59.
2. Select the site name for which you want to enable RVS and click
. The System Settings
window is displayed, as shown on page 60.
3. Click
. The Recording Verification System window is displayed, enabling you to
determine which sites should be monitored and notified about recording failures, as well as to set the
time between verifications.
4. Ensure the Activate Recording Verification checkbox is checked.
5. Specify how frequently the transmitters are checked for recording by selecting the required interval from
the Verification Time Interval, Time interval between verification cycles dropdown list (default = 5
Minutes).